peji

Intelligent Power Distribution Unit

Intelligent Power Distribution Unit

Newsunnakangwara simba rekugovera chikwata(iPDU) yakagadzirirwa kunyanya kutarisa uye kutonga simba munzvimbo dzedata, makamuri evhavha, uye zvimwe zvivakwa zvakakosha-zvinoita, zvichibvumira vatariri venzvimbo yedata kuti vatarise mashandisirwo emagetsi, kutevedzera mamiriro ezvakatipoteredza, uye kugamuchira yambiro kana magetsi akadzimwa kana zvimwewo. nyaya. Icho chikamu chakakosha chemazuva ano dhata data zvivakwa, ichipa epamberi masimba ekutonga uye yekutarisa masimba ayo anobatsira kuona yakavimbika uye inoshanda data data data.

Intelligent PDUs, inodaidzwawo kuti smart PDUs mayuniti epamberi ekugovera magetsi anopa huwandu hwemabhenefiti e data center optimization uye kugona kwesimba. Iine outlet-level metering, kure kure magetsi ekutarisa, uye mamwe maficha epamberi, akangwara maPDU anogonesa kwakaringana uye-chaiyo-nguva yekutarisa mashandisirwo emagetsi, achibvumira dhata data vanoshanda kuti vatarise kugovera kwesimba zvakanyanya uye zvinobudirira. Iyi nhanho yePDU yekutarisa uye manejimendi yakakosha pakuona kuita kwakakwana uye kuvimbika munzvimbo dzedata, sezvo ichigonesa vashandisi kuona nekugadzirisa nyaya dzemashandisirwo emagetsi nekukurumidza uye nyore.

Nekupa chaiyo-nguva data pakushandiswa kwesimba, akangwara maPDU anobatsirawo kuvandudza kugona kwesimba munzvimbo dzedata. Izvi zvinowanikwa kuburikidza nekuita kuti vashandisi vaone nzvimbo dzinogona kudzikiswa kushandiswa kwemagetsi, sekunge nekubatanidza mitoro yebasa kana kuvhara midziyo isingashandiswe. Iyi data zvakare inogonesa vashandisi kuti vatarise mafambiro ekushandisa simba nekufamba kwenguva, izvo zvinogona kuzivisa sarudzo nezve ramangwana kuronga kugona uye optimization yesimba.

Pamusoro pePDU yekutarisa uye manejimendi, akangwara maPDU anogona kubatanidzwa nemamwe madhata epakati manejimendi masisitimu, achigonesa yakazara data centre infrastructure management. Uku kubatanidzwa kunobvumira kutarisisa kwepakati uye kutonga kwekugovera kwemagetsi uye kushandiswa, kuderedza njodzi yenguva yekudzikira uye kuvandudza kwese kwese kutariswa kwenzvimbo.

Pakazere, itsika yekuisa iyo yakangwara PDU munzvimbo dzedata.

 

正1
反
Intelligent Power Distribution Unit-1 (1)
Intelligent Power Distribution Unit-2
Intelligent PDU

Key Features

· Webhu-Yakavakirwa manejimendi

Iyo yakazara-inoratidzirwa yewebhu-yakavakirwa GUI inopa intuitive uye inosvikika nzira yekugadzirisa yavo Intelligent PDUs, kutarisa mashandisirwo emagetsi, uye optimize simba rekushandisa munzvimbo dzavo dzedata kana makamuri maseva kubva kune chero PC yakabatana munharaunda.

1

· Configurable Alerts

Inonzwika uye E-Mail, zviziviso zveSMS zvinogona kugadziridzwa kuti izivise vashandisi nezvekuuya kwemagetsi akawandisa kana matambudziko etembiricha (neyesarudzo tembiricha uye humidity sensor) - kubatsira vashandisi kuchengetedza yavo A/V michina pakutadza.

1 alarm muganhu

· Tembiricha uye Humidity Monitoring

Iyo Tembiricha uye Humidity Sensor (Kutengeswa zvakasiyana) inobvumira zviziviso zveotomatiki kana kudzima-kudzima kwemidziyo kana tembiricha yepakati kana hunyoro hukakwira pamusoro pechikumbaridzo chakatsanangurwa nemushandisi - kudzivirira zvishandiso zvevashandisi kubva mukukundikana.

Mukuwedzera, kune sensor yemusuwo, smog sensor uye mvura yekucheka sensor yesarudzo.

TH sensor dhizaini

Mabasa Makuru

Newsunn intelligent PDU ine mamodheru mana maererano nemetering nekuchinja: 1. Total metering; 2. Kuchinja zvachose; 3. Outlet metering; 4. Outlet switching.

1.Total metering

Remote metering PDU basazvinosanganisira: yakazara ikozvino, voltage, simba rose, simba rose remagetsi, tembiricha, humidity, smog, matanda emvura, gadhi rekupinda nezvimwe.

2. Kuchinja zvachose

Dzora shanduko yedunhu rese nemodule imwechete.

2 muchidimbu
Total switch

3. Remote Outlet-by-Outlet metering

Tarisa ikozvino yeimwe neimwe yekubuda.

mita yekubuda

4.Remote Outlet-by-Outlet switching

Remote outlet kushandura PDUinosanganisira basa rekudzora switch yega yega yekubuda, kuseta yega yega yekunonoka nguva, kutumidza zita rekubuda, nezvimwe.

5

Newsunn yakangwara PDU inosanganisira mana mamodheru akavakirwa pamamita uye ekuchinja mabasa.

Type A: Yese metering + Yese switching + Individual outlet metering + Individual outlet switching

Type B: Total metering + Total switching

Type C: Total metering + Individual outlet metering

Type D: Total metering

Main basa

Murayiridzo wounyanzvi

Basa Mienzaniso

A

B

C

D

Metering

Total load current

Rodha ikozvino pane imwe neimwe yekubuda

On / Off mamiriro ega ega

Simba rese(kw)

Kushandiswa kwesimba rese(kwh)

Voltage yebasa

Frequency

Tembiricha/Humidity

Smog sensor

Door sensor

Sensor yekuchera mvura

Kuchinja

On/off of the power

Batidza/kudzima pane imwe neimwe nzira

Seta nguva yenguva yekutevedzana kwezvitoro pa/kudzima

Seta iyo yekubatidza / yekudzima nguva yeimwe neimwe yekubuda

Isa kukosha kwekugumira kualarm

Iyo yekuganhurira huwandu hwehuwandu hwekutakura ikozvino

Iyo yekumisikidza huwandu hwekuremerwa ikozvino pane imwe neimwe yekubuda

Iyo yekuganhurira huwandu hwevoltage yebasa

Kuganhurirwa kwemazinga ekushisa uye humidity

System otomatiki alarm

Yese inotakura ikozvino inodarika kukosha kwekumisikidza

Mutoro wazvino weimwe neimwe yekubuda inodarika kukosha kwekumisikidza

Tembiricha / Humidity inodarika kukosha kwekumisikidza

Smog

Kuchera mvura

Kuvhurwa kwegonhi

Kudzora module

Kudzora interface

 

Newsunn inogadzira mushandisi-ane hushamwari, intuitive, uye inosvikika interface yeinodzora module inosanganisira:

Chiratidziro cheLCD: inopa ruzivo rwechokwadi-nguva yemamiriro ePDU nemidziyo yayo yakabatana, inoratidza mashandisiro emagetsi, mamiriro ekubuda, mamiriro ezvakatipoteredza, uye rumwe ruzivo rwakakodzera.

Mabhatani: UP uye PASI mabhatani anobvumira peji kumusoro uye pasi kuona yega loop ikozvino, IP kero, baud mwero, mudziyo ID, nezvimwewo bhatani reMENU nderekuseta parameter.

Network Kubatana: Ethernet ports, iyo inobvumira vatariri kuti vatarise kure uye kutonga iyo PDU vachishandisa web-based management interface kana command-line interface.

Nzvimbo dzekukurukurirana: I / O port (Digital value input / output), RS485 port (Modbus protocol); USB port yekuwana console; Temp / Humidity port; Senor Port (yeutsi nemvura).

Operation Demo---- So Easy!!!

PDU Specification

Item

Parameter

Input

Input Type

AC 1-chikamu, AC 3-chikamu, 240VDC, 380VDC

Input Mode

3meter Power tambo ine yakataurwa plug

Input Voltage Range

100-277VAC/312VAC-418VAC/100VDC-240VDC/-43VDC- -56VDC

AC frequency

50/60Hz

Total load current

63A pamwero mukuru

Output

Output voltage rating

220 VAC, 250VAC,380VAC,-48VDC,240VDC,336VDC

Output frequency

50/60Hz

Output standard

6x IEC C13. Optional C19, German standard, UK standard, American standard, industrial sockets IEC 60309. Etc.

Output uwandu

48 zvitoro zvakanyanya

OEM & Customization

customization flow chart

Semuenzaniso, unogona kutsanangura chikumbiro chako sepazasi:

Quality Control

♦ Patent uye Certification

7
8

QC maitiro

A. Kuongorora Kwekuona: kuona kuti kunze kwePDU hakuna hurema hwemuviri, mavanga, kana kukuvadzwa, uye zvakare inoongorora kuti zvese zvinodikanwa zvinyorwa, mamakisi, uye mirairo yekuchengetedza iripo uye inonyoreka.

B. Kuongororwa kwekuchengetedzwa kwemagetsi: kuve nechokwadi chekuti PDU yakachengeteka nemagetsi kushandisa, kusanganisira

• Hi-pot test: 2000V high voltage test inovimbisa creepage kureba kwechigadzirwa uye inodzivirira kukanganisa kwetambo.

• Ground / insulation resistance test: inochengetedza kupikisa kwepasi maererano nemitemo yekuchengetedza, kuve nechokwadi chekuvhara zvachose pakati petambo yepasi nematanda.

• Kuchembera bvunzo: 48-awa online kuchembera bvunzo kuona zero kukundikana kwezvigadzirwa zvinounzwa kune vatengi.
•Muyedzo wekutakura: 120%

Test workshop

C. Kuedza basa: kuve nechokwadi chekuti ese maficha ePDU, senge zvitoro, mabreaker breakers, uye switch, uye remote control basa riri kushanda nemazvo.


Vaka yako PDU