Intelligent Power Distribution Unit
Newsunnakangwara simba rekugovera chikwata(iPDU) yakagadzirirwa kunyanya kutarisa uye kutonga simba munzvimbo dzedata, makamuri evhavha, uye zvimwe zvivakwa zvakakosha-zvinoita, zvichibvumira vatariri venzvimbo yedata kuti vatarise mashandisirwo emagetsi, kutevedzera mamiriro ezvakatipoteredza, uye kugamuchira yambiro kana magetsi akadzimwa kana zvimwewo. nyaya. Icho chikamu chakakosha chemazuva ano dhata data zvivakwa, ichipa epamberi masimba ekutonga uye yekutarisa masimba ayo anobatsira kuona yakavimbika uye inoshanda data data data.
Intelligent PDUs, inodaidzwawo kuti smart PDUs mayuniti epamberi ekugovera magetsi anopa huwandu hwemabhenefiti e data center optimization uye kugona kwesimba. Iine outlet-level metering, kure kure magetsi ekutarisa, uye mamwe maficha epamberi, akangwara maPDU anogonesa kwakaringana uye-chaiyo-nguva yekutarisa mashandisirwo emagetsi, achibvumira dhata data vanoshanda kuti vatarise kugovera kwesimba zvakanyanya uye zvinobudirira. Iyi nhanho yePDU yekutarisa uye manejimendi yakakosha pakuona kuita kwakakwana uye kuvimbika munzvimbo dzedata, sezvo ichigonesa vashandisi kuona nekugadzirisa nyaya dzemashandisirwo emagetsi nekukurumidza uye nyore.
Nekupa chaiyo-nguva data pakushandiswa kwesimba, akangwara maPDU anobatsirawo kuvandudza kugona kwesimba munzvimbo dzedata. Izvi zvinowanikwa kuburikidza nekuita kuti vashandisi vaone nzvimbo dzinogona kudzikiswa kushandiswa kwemagetsi, sekunge nekubatanidza mitoro yebasa kana kuvhara midziyo isingashandiswe. Iyi data zvakare inogonesa vashandisi kuti vatarise mafambiro ekushandisa simba nekufamba kwenguva, izvo zvinogona kuzivisa sarudzo nezve ramangwana kuronga kugona uye optimization yesimba.
Pamusoro pePDU yekutarisa uye manejimendi, akangwara maPDU anogona kubatanidzwa nemamwe madhata epakati manejimendi masisitimu, achigonesa yakazara data centre infrastructure management. Uku kubatanidzwa kunobvumira kutarisisa kwepakati uye kutonga kwekugovera kwemagetsi uye kushandiswa, kuderedza njodzi yenguva yekudzikira uye kuvandudza kwese kwese kutariswa kwenzvimbo.
Pakazere, itsika yekuisa iyo yakangwara PDU munzvimbo dzedata.
Key Features
· Webhu-Yakavakirwa manejimendi
Iyo yakazara-inoratidzirwa yewebhu-yakavakirwa GUI inopa intuitive uye inosvikika nzira yekugadzirisa yavo Intelligent PDUs, kutarisa mashandisirwo emagetsi, uye optimize simba rekushandisa munzvimbo dzavo dzedata kana makamuri maseva kubva kune chero PC yakabatana munharaunda.
· Configurable Alerts
Inonzwika uye E-Mail, zviziviso zveSMS zvinogona kugadziridzwa kuti izivise vashandisi nezvekuuya kwemagetsi akawandisa kana matambudziko etembiricha (neyesarudzo tembiricha uye humidity sensor) - kubatsira vashandisi kuchengetedza yavo A/V michina pakutadza.
· Tembiricha uye Humidity Monitoring
Iyo Tembiricha uye Humidity Sensor (Kutengeswa zvakasiyana) inobvumira zviziviso zveotomatiki kana kudzima-kudzima kwemidziyo kana tembiricha yepakati kana hunyoro hukakwira pamusoro pechikumbaridzo chakatsanangurwa nemushandisi - kudzivirira zvishandiso zvevashandisi kubva mukukundikana.
Mukuwedzera, kune sensor yemusuwo, smog sensor uye mvura yekucheka sensor yesarudzo.
Mabasa Makuru
Newsunn intelligent PDU ine mamodheru mana maererano nemetering nekuchinja: 1. Total metering; 2. Kuchinja zvachose; 3. Outlet metering; 4. Outlet switching.
1.Total metering
Remote metering PDU basazvinosanganisira: yakazara ikozvino, voltage, simba rose, simba rose remagetsi, tembiricha, humidity, smog, matanda emvura, gadhi rekupinda nezvimwe.
2. Kuchinja zvachose
Dzora shanduko yedunhu rese nemodule imwechete.
3. Remote Outlet-by-Outlet metering
Tarisa ikozvino yeimwe neimwe yekubuda.
4.Remote Outlet-by-Outlet switching
Remote outlet kushandura PDUinosanganisira basa rekudzora switch yega yega yekubuda, kuseta yega yega yekunonoka nguva, kutumidza zita rekubuda, nezvimwe.
Newsunn yakangwara PDU inosanganisira mana mamodheru akavakirwa pamamita uye ekuchinja mabasa.
Type A: Yese metering + Yese switching + Individual outlet metering + Individual outlet switching
Type B: Total metering + Total switching
Type C: Total metering + Individual outlet metering
Type D: Total metering
Main basa | Murayiridzo wounyanzvi | Basa Mienzaniso | |||
A | B | C | D | ||
Metering | Total load current | ● | ● | ● | ● |
Rodha ikozvino pane imwe neimwe yekubuda | ● | ● | |||
On / Off mamiriro ega ega | ● | ● | |||
Simba rese(kw) | ● | ● | ● | ● | |
Kushandiswa kwesimba rese(kwh) | ● | ● | ● | ● | |
Voltage yebasa | ● | ● | ● | ● | |
Frequency | ● | ● | ● | ● | |
Tembiricha/Humidity | ● | ● | ● | ● | |
Smog sensor | ● | ● | ● | ● | |
Door sensor | ● | ● | ● | ● | |
Sensor yekuchera mvura | ● | ● | ● | ● | |
Kuchinja | On/off of the power | ● | ● | ||
Batidza/kudzima pane imwe neimwe nzira | ● | ||||
Seta nguva yenguva yekutevedzana kwezvitoro pa/kudzima | ● | ||||
Seta iyo yekubatidza / yekudzima nguva yeimwe neimwe yekubuda | ● | ||||
Isa kukosha kwekugumira kualarm | Iyo yekuganhurira huwandu hwehuwandu hwekutakura ikozvino | ● | ● | ● | ● |
Iyo yekumisikidza huwandu hwekuremerwa ikozvino pane imwe neimwe yekubuda | ● | ● | |||
Iyo yekuganhurira huwandu hwevoltage yebasa | ● | ● | ● | ● | |
Kuganhurirwa kwemazinga ekushisa uye humidity | ● | ● | ● | ● | |
System otomatiki alarm | Yese inotakura ikozvino inodarika kukosha kwekumisikidza | ● | ● | ● | ● |
Mutoro wazvino weimwe neimwe yekubuda inodarika kukosha kwekumisikidza | ● | ● | ● | ● | |
Tembiricha / Humidity inodarika kukosha kwekumisikidza | ● | ● | ● | ● | |
Smog | ● | ● | ● | ● | |
Kuchera mvura | ● | ● | ● | ● | |
Kuvhurwa kwegonhi | ● | ● | ● | ● |
Kudzora module
Newsunn inogadzira mushandisi-ane hushamwari, intuitive, uye inosvikika interface yeinodzora module inosanganisira:
Chiratidziro cheLCD: inopa ruzivo rwechokwadi-nguva yemamiriro ePDU nemidziyo yayo yakabatana, inoratidza mashandisiro emagetsi, mamiriro ekubuda, mamiriro ezvakatipoteredza, uye rumwe ruzivo rwakakodzera.
Mabhatani: UP uye PASI mabhatani anobvumira peji kumusoro uye pasi kuona yega loop ikozvino, IP kero, baud mwero, mudziyo ID, nezvimwewo bhatani reMENU nderekuseta parameter.
Network Kubatana: Ethernet ports, iyo inobvumira vatariri kuti vatarise kure uye kutonga iyo PDU vachishandisa web-based management interface kana command-line interface.
Nzvimbo dzekukurukurirana: I / O port (Digital value input / output), RS485 port (Modbus protocol); USB port yekuwana console; Temp / Humidity port; Senor Port (yeutsi nemvura).
Operation Demo---- So Easy!!!
PDU Specification
Item | Parameter | |
Input | Input Type | AC 1-chikamu, AC 3-chikamu, 240VDC, 380VDC |
Input Mode | 3meter Power tambo ine yakataurwa plug | |
Input Voltage Range | 100-277VAC/312VAC-418VAC/100VDC-240VDC/-43VDC- -56VDC | |
AC frequency | 50/60Hz | |
Total load current | 63A pamwero mukuru | |
Output | Output voltage rating | 220 VAC, 250VAC,380VAC,-48VDC,240VDC,336VDC |
Output frequency | 50/60Hz | |
Output standard | 6x IEC C13. Optional C19, German standard, UK standard, American standard, industrial sockets IEC 60309. Etc. | |
Output uwandu | 48 zvitoro zvakanyanya |
OEM & Customization
Semuenzaniso, unogona kutsanangura chikumbiro chako sepazasi:
- IP manejimendi yakatwasuka PDU(yakazara metering), Single phase, 36xC13 + 6xC19, 1x32A, MCB, 7.2 kW, 3 m tambo yemagetsi neIEC60309 plug;
- Intelligent 3-chikamu PDU(yakazara uye yega metering), 36xC13 + 6xC19, 3x16A, MCB3, 11 kW, 3 m tambo yemagetsi neIEC60309 plug;
- 19inch 1U yakangwara PDU(yakazara uye yekubuda metering uye switching), 6xC13, 3 m tambo yemagetsi ine Schuko plug;
- Vertical basic C13 3-phase PDU, 6xC19+36xC13, ine IEC60309 380V/16A plug;
- 19inch 1U rack gomo PDU, 16A, 250V, 8x Schuko outlets uye 1.8m yakadzikwa tambo yemagetsi (1.5m2), ine master switch uye circuit breaker;
- 19inch 1U C19 PDU, 10A, 250V, 8x C13, C14 socket yekupinda, shandura uye overload mudziviriri;
- 19” 1U C13 inovharika PDU, 10A/250V, 8xC13 nekiyi, chinja uye overload mudziviriri, akaiswa tambo yemagetsi neSchuko plug 3.0 m;
- Rack gomo UK mhando PDU, 13A, 250V, 8xUK zvitoro, ine master switch, uye 3m yakadzikwa tambo yemagetsi (1.5m2);
- 19" network cabinet 1U NEMA PDU, 15A, 250V, 8xNEMA zvitoro, zvine master switch, uye 3m tambo yemagetsi yakadzikwa (1.5m2)
Quality Control
♦ Patent uye Certification
QC maitiro
A. Kuongorora Kwekuona: kuona kuti kunze kwePDU hakuna hurema hwemuviri, mavanga, kana kukuvadzwa, uye zvakare inoongorora kuti zvese zvinodikanwa zvinyorwa, mamakisi, uye mirairo yekuchengetedza iripo uye inonyoreka.
B. Kuongororwa kwekuchengetedzwa kwemagetsi: kuve nechokwadi chekuti PDU yakachengeteka nemagetsi kushandisa, kusanganisira
• Hi-pot test: 2000V high voltage test inovimbisa creepage kureba kwechigadzirwa uye inodzivirira kukanganisa kwetambo.
• Ground / insulation resistance test: inochengetedza kupikisa kwepasi maererano nemitemo yekuchengetedza, kuve nechokwadi chekuvhara zvachose pakati petambo yepasi nematanda.
• Kuchembera bvunzo: 48-awa online kuchembera bvunzo kuona zero kukundikana kwezvigadzirwa zvinounzwa kune vatengi.
•Muyedzo wekutakura: 120%
C. Kuedza basa: kuve nechokwadi chekuti ese maficha ePDU, senge zvitoro, mabreaker breakers, uye switch, uye remote control basa riri kushanda nemazvo.